The Sizing & Selection of Hydrocyclones
relationship which can be used to calculate the reduced recovery. This recovery, along with the bypassed solids, is used to predict the complete size distribution for the underflow product. R r = e 4X - 1 (eq. 1) e4X + e4 –2 Where R r = Recovery to underflow on corrected basis. X = Particle diameter /D50 C particle diameter.